Thermal electrical resistance (thermal voltage) verification simulatorClick on the picture to zoom in.
PRODUCT SPECIFICATIONS
VISCON-SC-100
Thermal electrical resistance (thermal voltage) verification simulator
Thermal electrical resistance (thermal electrode) calibration machine, thermoelectrically resistant thermoelectrically resistant electrocutor (thermal electrode) verification machine
01
Classification: Thermal and electrical resistance (thermal voltage) verification simulation
02
Check configuration based on field work
TECHNICAL SPECIFICATIONS
Technical specifications
Check the specifications against your operating conditions and use the selection tables to confirm your order configuration.
View selection tables ↓| Model | VISCON-SC-100 |
|---|---|
| Operating principle | Internalized high stable electrical resistance network and low drift D/A Source, press IEC 60751 / IEC 60584 The fraction scale converts the given temperature to the corresponding resistance value or thermoelectric EMF Output, replace scene. RTD, thermocouple Secondary instrument, temperature. transmitter, DCS/PLC Temperature channels are available Standard signal; at the same time measure the output current and voltage of the tested instrument |
| Simulation Type | RTD (RTD) Simulation, thermocouple (TC) Simulation, resistance output, direct flow millivol output; and can measure electrical resistance, millivolt, current current and voltage |
| RTD type | Pt100, Pt1000, Pt10, Cu50, Cu100, Cu53, Ni1000 (optional BA1, BA2, G53 (Advanced) |
| Thermocouple type | K, E, J, T, N, S, R, B, WRe3-WRe25 (optional U, L Type) |
| RTD Range | -200–+850℃ (Pt100); -200–+300℃ (Cu50/Cu100); resolution 0.01℃ |
| Thermocouple Range | K, E, J, T, N:-200–+1300℃; S, R:0–+1768℃; B:600–+1820℃; resolution 0.1℃ |
| Output Accuracy | RTD: ±0.05℃ (-100–+400℃ Paragraph), remaining paragraphs ±0.1℃; thermocouple: ±0.3℃ (K/E/J/T/N), ±1.0℃ (S/R/B;mv output ± (0.02%RD+5μV) |
| Wiring | RTD supports the two-line system, three-wire, four-wire imitation (three-wire wiring electrical resistance compensation 0–20Ω); Thermocouple is a two-line system with an internal reference end |
| Reference junction treatment | Internal cold junction compensation (Automated, Compensated accuracy ±0.3℃); fixed reference end temperature (0℃/25℃ / custom); external ice point bottle access supported |
| Output mode | Fixed output, step output (spacing and stay time), slope output (slash ℃/min), program segment output (maximum 10, cycle) |
| Simultaneous measurement | Direct current 0–25.000mA (±0.02%RD+2μA), direct current voltage 0–30VDC (±0.02%RD), electrical resistance 0–4000Ω (±0.05%RD) |
| Loop power | Internal DC 24V loop power supply (with short roads and reverse polarity protection) can power the measured temperature transmitter and read its output 4–20mA at the same time |
| Conversion function | Temperature and resistance/ thermoelectric EMF positive reverse check; current and temperature (percentage) linear conversion; output 0–100% %FS directly |
| Display type | 3.5 inch colored liquid crystal, double row display (set value + measured), with back light; full Chinese menu |
| Data management | Stored 200 group check point data, USB export CSV; support fixed points with one key to zero |
| Communication interface | USB (standard)/ RS232 (Optional) |
| Power supply | Chargeable lithium batteries 3.7V / 3000mAh, working continuously ≥12h USB charging to support mobile power supply |
| Operating environment | Temperature -10–+50℃, relative humidity ≤90%RH (Non-condensing) |
| Overall dimensions | About 185 × 95 × 42mm (excluding condoms) |
| Instrument weight | About 0.55kg (including batteries) |
| Applicable standards | JJG 617 Digital Temperature Indicator Control/ JJG 874 Temperature Indicator Control/ JJG 229 Industrial Platinum, Copper RTD / JJG 351 Work-free Metal thermocouple / IEC 60751 / IEC 60584 |
| Typical applications | On-site calibration and simulation of temperature transmitter, motion circles and numerical thermometers, paperless recorder, DCS/PLC temperature Input channels; Dial debugging to replace uninstalled thermostats and achieve back-tracking |
| Product features | Typical RTD and TC pictograms, free of multiple Standard electrical resistance and mvolt sources; RTD Three-wire wiring electrical resistance, i.e. closer to real components; program output simulations of heating/reducing processes, allowing the verification of Alarm and the recording curve; temperature and current Display, Transmitter verification of one connection completed |
Product selection
VISCON-SC-100| Code | Instrument type |
|---|---|
| T1 | RTD simulation (RTD) |
| T2 | Thermocouple simulation (TC) |
| T3 | Temperature complex (RTD + TC, Standard) |
| T4 | Temperature + electrometric composite |
| Code | RTD type |
|---|---|
| A1 | Pt100 / Cu50 / Cu100 (Typical) |
| A2 | A1 + Pt1000 / Pt10 |
| A3 | A2 + Ni1000 / Cu53 |
| A4 | A3 + BA1/BA2/G53 (old score) |
| Code | Thermocouple type |
|---|---|
| B1 | K / E / J / T (Typical) |
| B2 | B1 + N |
| B3 | B2 + S / R / B (precious metals) |
| B4 | B3 + WRe3-WRe25 / U / L |
| Code | Output Accuracy |
|---|---|
| C1 | ±0.05℃ (RTD) / ±0.3℃ (TC), Standard |
| C2 | ±0.02℃ (RTD) / ±0.2℃ (TC) Accuracy |
| C3 | ±0.1℃ (RTD) / ±0.5℃ (TC), Economy type |
| Code | Wiring configuration |
|---|---|
| W1 | A two-line system |
| W2 | Three-wire (with lead wires for electrical resistance) |
| W3 | Four-wire |
| W4 | Second/third/fourth line toggle (Standard) |
| Code | Additional functions |
|---|---|
| F1 | Staple + Step Output |
| F2 | F1 + ramp output |
| F3 | F2 + program segment output (≤10) |
| F4 | F3 + data storage and USB export |
| Code | Loop power supply |
|---|---|
| P1 | Loop power supply |
| P2 | DC 24V Loop power supply (with protection) |
| P3 | DC 24V + Synthetic current measurements |
| Code | Accessory configuration |
|---|---|
| K1 | Standard test line group + condoms |
| K2 | K1 + Ice point bottles (reference end) |
| K3 | K1 + backup batteries and chargers |
Confirm specifications and ordering options
Contact us with the measurement target, operating conditions, and installation requirements to confirm your configuration.