Process signal simulationClick on the picture to zoom in.
PRODUCT SPECIFICATIONS
VISCON-SC-150
Process signal simulation
Process signal simulation calibration, process signal calibration
01
Classification: Process signal simulation
02
Check configuration based on field work
TECHNICAL SPECIFICATIONS
Technical specifications
Check the specifications against your operating conditions and use the selection tables to confirm your order configuration.
View selection tables ↓| Model | VISCON-SC-150 |
|---|---|
| Operating principle | Double channel D/A and A/D circuit, one channel output Standard process signal (electricity/voltage/resistance/frequency/temperature) and the other channel Simultaneous measurement exported from the inspected device, which constitutes closed ring verification; interior Loop power supply power supply Transmitter to achieve integrated field verification |
| Channel configuration | Two channels capable of simultaneous output and measurement (output channel 1 + survey channel 1); two channels of electrical separation isolation voltage 500V |
| Signal output | Direct current 0–25.000mA, direct current 0–12.000V, mvolt -10–100.000mV, resistance 0–4000.0Ω, frequency 0–10.000kHz (square wave/ pulse, range 5–24V available) |
| Signal measurement | Direct current 0–25.000mA, direct current 0–30.000V, mv -10–100.000mV, electrical resistance 0–4000.0Ω, frequency 0–50.00kHz, break (≤200Ω JO) |
| Temperature Simulation | RTD:Pt100/Pt1000/Cu50/Cu100, 2/3/ 4 lines; -200–850℃; TC:K/E/J/T/N/S/R/B, -20 0–1800℃; inline Cold junction compensation |
| Basic Accuracy | Electricity/voltage: ± (0.02%RD+2μA / +0.2mV); electrical resistance: ±0.05%RD; frequency: ±0.01%RD; temperature: ±0.3℃ (TC)/ ±0.1℃ (RTD) |
| Output mode | Fixed values, steps (automatic/manual, long steps and presence), slopes (slashable and time), procedure segments (≤20, 0–100% % output) |
| Loop power supply | Internal DC 24V / 30mA loop power supply (with short circuits and reverse polarity protection); with HART barrier interface, which can be used in conjunction with HART handheld |
| HART communication | Optional HART modem module to support reading transmitter PV / range /bit and can mA value superimpose HART numeric volume comparison (used for backtracking) |
| Calculation functions | Error reading (fixing value deviation from inspected value and percentage), range conversion, square root/linear flow conversion, valve opening (%) conversion, unit conversion |
| Data management | Internal storage ≥2000 group (with time stamp), USB export CSV/Excel; continuous record support (sampling interval 1s–60s) |
| Display type | 4.3 inch colour TFT, 3rd sector Display (output value / measured value / deviation), with back light; graphical menu |
| Communication interface | USB (standard)/ RS232 (standard); optional Bluetooth 5.0 (connecting mobile phone APP or on-board) |
| Power supply | Chargeable lithium batteries 7.4V / 4000mAh, working continuously ≥16h; AC 220V adapter charge to support side-loading |
| Operating environment | Temperature -10–+50℃, relative humidity ≤90%RH (Non-condensing) |
| Ingress protection | IP54 (standard); optional IP65 |
| Overall dimensions | 210 × 105 × 48mm |
| Instrument weight | About 0.85kg (including batteries) |
| Applicable standards | JJG 882 Pressure transmitter / JJG 617 Digital temperature indicator adjuster/ JJF 1472 Process instrument calibration instruction/ GB/T 17626 (EMC) |
| Typical applications | Differential pressure / Temperature/ level transmitter output verification, control valve and actuator opening command, variable frequency drive debugging with PLC analogue channel, Pulse flow computer and calculator verification, and imitation of signal before metering back to transport |
| Product features | One-time coverage mA, V, mV, Ω, Hz 6 large temperature signals, replacing the traditional multiple single function calibration; two-channel isolation, one side to the other transmitter adding a signal while reading back the output;inline HART Resistor with Loop power supply, no additional equipment is required on site; the program segment output replicable process curves to facilitate locking with Alarm Authentication |
Product selection
VISCON-SC-150| Code | Channel configuration |
|---|---|
| C1 | Single channel (output or measurement) |
| C2 | Double-channel isolation (output + measurements, Standard) |
| C3 | Double channel + Loop power supply |
| Code | Signal range |
|---|---|
| S1 | 4–20mA / 0–10V (basic) |
| S2 | S1 + mV + electrical resistance |
| S3 | S2 + frequency/ Pulse |
| S4 | S3 + RTD Thermocouple (full functionality) |
| Code | Accuracy class |
|---|---|
| A1 | 0.02%RD (Standard) |
| A2 | 0.05%RD |
| A3 | 0.01%RD (high Accuracy, order) |
| Code | HART functionality |
|---|---|
| H1 | HART |
| H2 | With HART interceptor interface |
| H3 | Inline HART modem (readable Transmitter Configuration) |
| Code | Output mode |
|---|---|
| M1 | Fixed Output |
| M2 | M1 + step output |
| M3 | M2 + ramp output |
| M4 | M3 + process segment (≤20) |
| Code | Data and records |
|---|---|
| D1 | No storage |
| D2 | Storage 2000 group + USB Export |
| D3 | D2 + Continuous records (1–60s interval) |
| Code | Communication interface |
|---|---|
| R1 | USB |
| R2 | USB + RS232 (Standard) |
| R3 | R2 + Bluetooth 5.0 |
| Code | Protection and power supply |
|---|---|
| P1 | IP54 + lithium batteries (≥16h) |
| P2 | IP65 + lithium batteries (≥16h) |
| P3 | IP65 + large capacity batteries (≥30h) |
Confirm specifications and ordering options
Contact us with the measurement target, operating conditions, and installation requirements to confirm your configuration.
Contact us