Heat gauge checkerClick on the picture to zoom in.
PRODUCT SPECIFICATIONS
VISCON-SC-200
Heat gauge checker
Thermal instrumentation, thermal instrumentation.
01
Classification: Thermal instrumentation
02
Check configuration based on field work
TECHNICAL SPECIFICATIONS
Technical specifications
Check the specifications against your operating conditions and use the selection tables to confirm your order configuration.
View selection tables ↓| Model | VISCON-SC-200 |
|---|---|
| Operating principle | Host integrated temperature and Electrical signals output measurement circuits with plug-in pressure module interfaces; integrated power supply, collection and Display from host after plugging in the pressure module to form temperature, pressure, Electrical signals triangulation of thermal instrumentation platform |
| Pressure module | Plug-in smart pressure module (i.e. plug-in, automatic recognition range and numbering); -100kPa–60MPa, typical 0–100kPa/600kPa/1.6MPa/6MPa/25MPa/60MPa, differential pressure 0–10kPa/1.6MPa, absolute pressure 0–100kPa/2.5MPa optional, 1–3 for each machine only |
| Pressure Accuracy | 0.05%FS (standard module), 0.02%FS (high accuracy module); ≤0.05%FS /year stability |
| Temperature signal | RTD:Pt100/Pt1000/Cu50/Cu100, 2/3/ 4 lines, -200–850℃; TC:K/E/J/T/N/S/R/B, -20 0–1800℃; inline cold junction compensation (±0.3℃) |
| Electrical signals | Output/measurement: 4–20mA (0–25mA), 0–10V (0–30V), mV (-10–100mV), electrical resistance (0 –4000Ω), frequency (0–10kHz), breakdown |
| Basic Accuracy | Electricity current voltage ± (0.02%RD+2μA); electrical resistance ±0.05%RD;frequency ±0.01%RD;the temperature ±0.3℃ (TC)/ ±0.1℃ (RTD); stress ±0.05%FS |
| Loop power supply | Internal DC 24V / 30mA loop power supply (with protection) with HART barrier interface |
| HART communication | Standard Configure HART Modem: Read transmitter PV range, bits, diagnostic information; support mA vs HART |
| Calibration functions | Pressure / Differential pressure transmitter verification (pressure reading of currents, 4 / 5 Linearity error read directly), temperature Transmitter verification, pressure release concern replacement capture, leakage security, flow calculator Pulse verification, Control valve open |
| Calculation and evaluation | Errors and return error read-through, percentage error, range conversion, square root flow conversion; eligible or not according to JJG 882, JJG 617 program |
| Output mode | Fixed value, step, slope, procedure segment (≤20 % 0–100% |
| Data management | Internal storage ≥4000 group (pressure, current, temperature, time stamp), USB export CSV; Optional on-site printing (Bluetooth microprinter) |
| Display type | 5 inch colour TFT, up to sector 4 Display (pressure/electric current/temperature/distortion); visible under strong light |
| Communication interface | USB (standard)/ RS232 (standard) / Bluetooth 5.0 (standard); optional RS485 |
| Power supply | Chargeable lithium batteries 7.4V / 5200mAh, continuous work ≥14h (pressure module); AC 220V adapter to support side loads |
| Operating environment | Temperature -10–+50℃, relative humidity ≤90%RH; pressure module temperature 0–50℃ |
| Ingress protection | IP54 (host standard); optional IP65 |
| Overall dimensions | Host 230 × 120 × 55mm; pressure module 60 × 40mm |
| Instrument weight | Host 1.1kg; pressure module 0.15kg |
| Applicable standards | JJG 882 Pressure transmitter / JJG 875 Digital Pressureometer/ JJG 617 Digital Temperature Indicator/ JJG 229 / JJG 351 / JJF 1472 Procedures meter calibration norms |
| Typical applications | Fire power plants and nuclear power plant thermal workshops, unit rehabilitation sites, examination and verification of pressure/ Differential pressure transmitter, temperature Transmitter, pressure switches, flow calculator, Control valve; also for petrochemical, heat supply, water treatment. |
| Product features | Temperature, pressure, electrical signals triangulation, covered by a heater's specialty; pressure module can be inserted, range selected for the prosecution and delivered to the prosecution, range, HART configured for Standard smart Transmitter free handheld; error reading and protocol determination can lead to conclusions on the ground |
Product selection
VISCON-SC-200| Code | Pressure module |
|---|---|
| P1 | Non-pressure module (temperature + Electrical signals) |
| P2 | Includes 1 pressure module only (Range optional) |
| P3 | 2 pressure module only |
| P4 | 3 pressure module only |
| Code | Module Range |
|---|---|
| R1 | 0–100kPa / 600kPa (micropressure) |
| R2 | 0–1.6MPa / 6MPa (Typical) |
| R3 | 0–25MPa / 60MPa (high pressure) |
| R4 | Differential pressure 0–10kPa / 1.6MPa |
| R5 | Absolute pressure 0–100kPa / 2.5MPa |
| Code | Module Accuracy |
|---|---|
| A1 | 0.05%FS (Standard) |
| A2 | 0.02%FS (high Accuracy) |
| A3 | 0.1%FS (Economy type) |
| Code | Temperature function |
|---|---|
| T1 | RTD imitation (Pt100/Cu50) |
| T2 | RTD + TC(K/E/J/T) |
| T3 | RTD + TC full score (include S/R/B) |
| Code | HART configuration |
|---|---|
| H1 | HART barrier interface |
| H2 | Inline HART modem (Standard) |
| Code | Data and Printing |
|---|---|
| D1 | Storage 4000 group + USB Export |
| D2 | D1 + Bluetooth miniprinter |
| D3 | D2 + cell phone APP report |
| Code | Communication interface |
|---|---|
| C1 | USB + RS232 (Standard) |
| C2 | C1 + Bluetooth 5.0 |
| C3 | C2 + RS485 |
| Code | Protection and power supply |
|---|---|
| B1 | IP54 + lithium batteries (≥14h) |
| B2 | IP65 + lithium batteries (≥14h) |
| B3 | IP65 + large capacity batteries (≥24h) |
Confirm specifications and ordering options
Contact us with the measurement target, operating conditions, and installation requirements to confirm your configuration.
Contact us