Wall-mounted rapid digital thermometerClick on the picture to zoom in.

PRODUCT SPECIFICATIONS

VISCON-TEMP-100

Wall-mounted rapid digital thermometer

Wall-mounted rapid digital thermometer, wall-mounted rapid digital thermometer

01

Classification: walled rapid digital thermometer

02

Check configuration based on field work

⁇ Return wall-mounted rapid digital thermometer classification

TECHNICAL SPECIFICATIONS

Technical specifications

VISCON-TEMP-100

Check the specifications against your operating conditions and use the selection tables to confirm your order configuration.

View selection tables ↓
ModelVISCON-TEMP-100
Product functionMagnify, linearly and in big words the faint signals of the temperature sensors. Display On the walls of a workshop, a grain warehouse, a freezer or a farmhouse, visible at least a few dozen metres away; inside, quick sampling and Adjustable Filtering, balancing reaction speed with readings, for situations where temperature changes need to be reflected in a timely manner
Temperature range-50–+300℃ (Pt100 standard (a) Tranche; optional -200–+400℃ (wide area) Pt1000), 0–600℃, 0–1000℃ (with: K Type thermocouple; also available 4–20mA Temperature Transmitter Press Range Linear conversion
Sensor TypePt100 / Pt1000 second line or three-wire, Cu50, K / E / J thermocouple, 4–20mA Transmitter input; one instrument corresponds to one type of input, specified when ordering
Measurement accuracy±0.2℃ ±1 (Pt100, -50–+200℃ area); the rest range ±0.5℃; thermocouple ±0.5%FS, incorporated cold junction compensation (in error ±0.5℃)
Response timeT90 ≤3s (with φ4 mineral-insulated Pt100, medium flow speed ≥0.5m/s); sampling cycle 200ms; digital filter 0–15 can be set, allowing a trade-off between keeping up quickly and reading well
Display unit4 bit 7 segment bright red LED high 100mm (optional 57 / 150 / 200mm); brightness 8 class adjustable, dark environment can be reduced to 20% to avoid octopus at night; negative temperature at maximum Display minus sign
Viewing distance100mm approximately 30m optional 57mm 15m 150mm approximately 45m 200mm approximately 60m
Resolution0.1℃ (-99.9–+99.9℃ area); automatically converted 1℃ Display beyond that area to avoid the last beat interference reading
Function AlarmAlarm, hysteresis 0.1–9.9℃ available; 250VAC/2A numeric blinking and driving relays beyond the limit; alarm delay 0–999s available to avoid short-lived fluctuations caused by open doors and inputs
Transmitter outputOptional 1 road 4–20mA (as linear range, load ≤500Ω) or 0–10V for PLC, DCS, or recorder to collect, board and system at the same time
Communication interfaceOptional RS485 (Modbus RTU), remotely readable temperature, modified alarm; optional LoRa wireless module, save long distance signal lines
Recording functionsOptional inline 2MB storage device recorded at 1–60min to save 30000; data exported by RS485 CSV for cold chain and food tracking
Power supplyAC 85–265V or DC 24V It's the work ≤6VA; optional Inline lithium batteries, maintained after power cuts display With records ≥72h
Housing and ingress protectionAluminium alloy-type frame + Yakli panel, wall-mounted; protection IP65 (dustproof, spray-resistant) with stainless casings that can be used in wet workshops, freezer exterior walls and rinse environment
MountingFour wall-mounted holes on the back, which can also be attached to a hanger or a pole; sensor line entering via PG9 waterproof connection, three-wire lead line maximum 100m
Overall dimensions400 × 200 × 60mm (word 100mm type); optional 300×150×55mm (57mm font high)/ 600×300×70mm (200mm font high)
Environmental conditions-20–+60℃, humidity ≤95%RH Non-condensing; detector side by selected sensor's temperature tolerance range
Instrument weightAbout 2.2kg (high 100mm type)
Applicable standardsGB/T 34037 / JB/T 8214 Refer / GB/T 17626 (EMC) /Refer JJG 617 (digital temperature indicator adjuster Verification regulation)
Typical applicationsTemperature monitoring of grain silos and drying towers, cooling and cooling vehicle temperature panels, farmhouses and greenhouses, workshop positions Ambient temperature tip, boiler room and heat exchange station return water temperature, ageing and test kits, asphalt and concrete maintenance room temperature control
Product features30m external readable without having to walk close copying; T90 ≤3s rapid response mix mineral-insulated probe to keep up with temperature changes in drying, cooling and input processes; IP65 aluminium shell can be used in wet and low temperature environments; the same table can be sent with values 4–20mA or RS485, both watchboard and harvest.

Product selection

VISCON-TEMP-100
Temperature range
CodeTemperature range
R1-50–+300℃ (Standard)
R2-200–+400℃ (wide area)
R30~600℃
R40~1000℃
R54–20mA Range (Specify when ordering)
Sensor Type
CodeSensor Type
S1Pt100 Three-wire (Standard)
S2Pt1000 2Direct
S3Cu50
S4K Thermocouple
S5E / J Thermocouple
S64–20mA Transmitter Input
Character height and viewing distance
CodeCharacter height and viewing distance
H5757mm high, about 15m
H100100mm high, about 30m (Standard)
H150150mm high, about 45m
H200200mm high, about 60m
Display colors
CodeDisplay colors
C1Red (Standard)
C2Green
C3Orange Yellow
C4Double colour, automatic colour transformation beyond limit
Alarms and outputs
CodeAlarms and outputs
O0No Alarm, no output (pure Display)
O1High and low limits 2 alarm + relays
O2O1 + 1 4–20mA (Standard)
O3O1 + 1 Road 0–10V
Communication interface
CodeCommunication interface
T0Communication
T1RS485(Modbus RTU)
T2RS485 + LoRa wireless
Recording functions
CodeRecording functions
M0No record
M12MB Record (approximately 30000)
M2M1 + Lithium Battery, blackout ≥72h
Power supply
CodePower supply
V1AC 220V(85~265V)
V2DC 24V
V3AC 220V + Battery backup

Confirm specifications and ordering options

Contact us with the measurement target, operating conditions, and installation requirements to confirm your configuration.

Contact us
VISCON-TEMP-100 Wall-Mounted Fast-Response Digital Thermometer