Wall-mounted rapid digital thermometerClick on the picture to zoom in.
PRODUCT SPECIFICATIONS
VISCON-TEMP-100
Wall-mounted rapid digital thermometer
Wall-mounted rapid digital thermometer, wall-mounted rapid digital thermometer
01
Classification: walled rapid digital thermometer
02
Check configuration based on field work
TECHNICAL SPECIFICATIONS
Technical specifications
Check the specifications against your operating conditions and use the selection tables to confirm your order configuration.
View selection tables ↓| Model | VISCON-TEMP-100 |
|---|---|
| Product function | Magnify, linearly and in big words the faint signals of the temperature sensors. Display On the walls of a workshop, a grain warehouse, a freezer or a farmhouse, visible at least a few dozen metres away; inside, quick sampling and Adjustable Filtering, balancing reaction speed with readings, for situations where temperature changes need to be reflected in a timely manner |
| Temperature range | -50–+300℃ (Pt100 standard (a) Tranche; optional -200–+400℃ (wide area) Pt1000), 0–600℃, 0–1000℃ (with: K Type thermocouple; also available 4–20mA Temperature Transmitter Press Range Linear conversion |
| Sensor Type | Pt100 / Pt1000 second line or three-wire, Cu50, K / E / J thermocouple, 4–20mA Transmitter input; one instrument corresponds to one type of input, specified when ordering |
| Measurement accuracy | ±0.2℃ ±1 (Pt100, -50–+200℃ area); the rest range ±0.5℃; thermocouple ±0.5%FS, incorporated cold junction compensation (in error ±0.5℃) |
| Response time | T90 ≤3s (with φ4 mineral-insulated Pt100, medium flow speed ≥0.5m/s); sampling cycle 200ms; digital filter 0–15 can be set, allowing a trade-off between keeping up quickly and reading well |
| Display unit | 4 bit 7 segment bright red LED high 100mm (optional 57 / 150 / 200mm); brightness 8 class adjustable, dark environment can be reduced to 20% to avoid octopus at night; negative temperature at maximum Display minus sign |
| Viewing distance | 100mm approximately 30m optional 57mm 15m 150mm approximately 45m 200mm approximately 60m |
| Resolution | 0.1℃ (-99.9–+99.9℃ area); automatically converted 1℃ Display beyond that area to avoid the last beat interference reading |
| Function Alarm | Alarm, hysteresis 0.1–9.9℃ available; 250VAC/2A numeric blinking and driving relays beyond the limit; alarm delay 0–999s available to avoid short-lived fluctuations caused by open doors and inputs |
| Transmitter output | Optional 1 road 4–20mA (as linear range, load ≤500Ω) or 0–10V for PLC, DCS, or recorder to collect, board and system at the same time |
| Communication interface | Optional RS485 (Modbus RTU), remotely readable temperature, modified alarm; optional LoRa wireless module, save long distance signal lines |
| Recording functions | Optional inline 2MB storage device recorded at 1–60min to save 30000; data exported by RS485 CSV for cold chain and food tracking |
| Power supply | AC 85–265V or DC 24V It's the work ≤6VA; optional Inline lithium batteries, maintained after power cuts display With records ≥72h |
| Housing and ingress protection | Aluminium alloy-type frame + Yakli panel, wall-mounted; protection IP65 (dustproof, spray-resistant) with stainless casings that can be used in wet workshops, freezer exterior walls and rinse environment |
| Mounting | Four wall-mounted holes on the back, which can also be attached to a hanger or a pole; sensor line entering via PG9 waterproof connection, three-wire lead line maximum 100m |
| Overall dimensions | 400 × 200 × 60mm (word 100mm type); optional 300×150×55mm (57mm font high)/ 600×300×70mm (200mm font high) |
| Environmental conditions | -20–+60℃, humidity ≤95%RH Non-condensing; detector side by selected sensor's temperature tolerance range |
| Instrument weight | About 2.2kg (high 100mm type) |
| Applicable standards | GB/T 34037 / JB/T 8214 Refer / GB/T 17626 (EMC) /Refer JJG 617 (digital temperature indicator adjuster Verification regulation) |
| Typical applications | Temperature monitoring of grain silos and drying towers, cooling and cooling vehicle temperature panels, farmhouses and greenhouses, workshop positions Ambient temperature tip, boiler room and heat exchange station return water temperature, ageing and test kits, asphalt and concrete maintenance room temperature control |
| Product features | 30m external readable without having to walk close copying; T90 ≤3s rapid response mix mineral-insulated probe to keep up with temperature changes in drying, cooling and input processes; IP65 aluminium shell can be used in wet and low temperature environments; the same table can be sent with values 4–20mA or RS485, both watchboard and harvest. |
Product selection
VISCON-TEMP-100| Code | Temperature range |
|---|---|
| R1 | -50–+300℃ (Standard) |
| R2 | -200–+400℃ (wide area) |
| R3 | 0~600℃ |
| R4 | 0~1000℃ |
| R5 | 4–20mA Range (Specify when ordering) |
| Code | Sensor Type |
|---|---|
| S1 | Pt100 Three-wire (Standard) |
| S2 | Pt1000 2Direct |
| S3 | Cu50 |
| S4 | K Thermocouple |
| S5 | E / J Thermocouple |
| S6 | 4–20mA Transmitter Input |
| Code | Character height and viewing distance |
|---|---|
| H57 | 57mm high, about 15m |
| H100 | 100mm high, about 30m (Standard) |
| H150 | 150mm high, about 45m |
| H200 | 200mm high, about 60m |
| Code | Display colors |
|---|---|
| C1 | Red (Standard) |
| C2 | Green |
| C3 | Orange Yellow |
| C4 | Double colour, automatic colour transformation beyond limit |
| Code | Alarms and outputs |
|---|---|
| O0 | No Alarm, no output (pure Display) |
| O1 | High and low limits 2 alarm + relays |
| O2 | O1 + 1 4–20mA (Standard) |
| O3 | O1 + 1 Road 0–10V |
| Code | Communication interface |
|---|---|
| T0 | Communication |
| T1 | RS485(Modbus RTU) |
| T2 | RS485 + LoRa wireless |
| Code | Recording functions |
|---|---|
| M0 | No record |
| M1 | 2MB Record (approximately 30000) |
| M2 | M1 + Lithium Battery, blackout ≥72h |
| Code | Power supply |
|---|---|
| V1 | AC 220V(85~265V) |
| V2 | DC 24V |
| V3 | AC 220V + Battery backup |
Confirm specifications and ordering options
Contact us with the measurement target, operating conditions, and installation requirements to confirm your configuration.
Contact us