View selection tables ↓| Model | VISCON-TR-100 |
|---|---|
| Product function | Precision for various bridge and passive sensors excitation supply Weak of it output signal Magnifying, filtering, linearization and standard Chemical processing, output 4–20mA / 0–10V / RS485 Send it directly. PLC, DCS or collecting cards to address the vulnerability of small signals to interference with long-range transmission |
| Compatible sensors | Resisting variants gravity/force/train sensor (350Ω/1000Ω bridge), diffused silicon with ceramic pressure sensor (mV output), LVDT (decomposition module), Thermocouple with RTD, Hall and Magnetic Electrovelocity transducer, wet sensitivity and pressure sensitivity elements |
| Excitation supply | Bridge pressure DC 5V / 10V programmable (load ≥350Ω, output current ≤60mA), or constant flow 1mA / 2mA (used RTD and semiconductor sensors); incentive stability ≤0.02%/℃ |
| Input signal | Mvol. -30–+30mV (resolution 1μV), voltage 0–±10V, current 4–20mA, electrical resistance 0–4kΩ, frequency 0–20kHz; thermocouple -10–100mV; RTD II/III/ Four-wire |
| Amplification and range | Gain 1–1000 multiple programmable (by 1, 2, 5); zero points and fullness can be fined independently to support any segment Range map and Range compression |
| Linearization | Internal multiform assembly (up to 9 linear or 3 stylistic) allowing correction of sensor non-linearity; support for sensor sensitivity entry (e.g. 2.0000mV/V) for direct conversion engineering units |
| Filter | 0.1–100Hz (Step II), 50/60Hz trap, mean filter (1–64); inhibition of vibrations and electromagnetic interference from the field |
| Output signal | 4–20mA (load ≤750Ω) / 0–10V / 1–5V / 0–5V toggle; optional RS485 (Modbus-RTU) Digital output and isolation relay Alarm output |
| Conversion accuracy | ±0.05%FS (23±2℃ with incentives and magnification); temperature drift ≤0.01%FS/℃; all-temperature -20–+60℃ ≤±0.2%FS |
| Response speed | Sampling rate 10/100/1000 per second; simulated output response ≤10ms (filtration closed); suitable for dynamic force and twist measurement |
| Special function | Peak / valley maintenance, peak capture (dynamic measurement), decorating (zeroing), unit conversion, sensor Open-circuit detection, super Range indicator; term heavy can be marked Full scale and multiple points |
| Isolation performance | Input - Output - communication Quadrelation; isolation voltage 1500VAC/1min; common-mode rejection ≥120dB; applicable to Variable frequency drive, servers, etc. |
| Configuration method | PC software with USB/RS485 Configuration, parameter electrocution; one-key tagging supported (alert/pressure automatic calculation of gain); and batch copy of supporting parameter |
| Display | Optional 4 bit LED digit Display (Display project value) or take over the marker holder |
| Power supply | DC 20–35V (Quota 24V); single channel power ≤1.8W (bridge pressure 10V/350Ω full load ≤2.6W) |
| Mounting | 35mm standard DIN rail trucking, or plug-in box centralized installation (optional); thickness 22.5mm (single channel) |
| Wiring | Plugged screws (2.5mm2), sensor incentive/sign/shield partitions, with shielded layers attached to ground endpoints |
| Operating environment | Temperature -20–+60℃, relative humidity ≤95%RH (Non-condensing) |
| Overall dimensions | 22.5 × 110 × 118mm (single channel) |
| Instrument weight | 0.18kg |
| Applicable standards | GB/T 17626 (EMC)/ IEC 61000-6-2 / GB/T 18271 (process measurement and control device performance assessment)/ JJG 391 (power sensor) |
| Typical applications | (b) Industrial measurement circuits for mass and distribution systems, force and twist test stations, mass collection of pressure sensors, position transfer and vibration monitoring, rotational measurements; and various types of on-site electromagnetic interference, long-range transmission of signals, non-linear properties of sensors requiring correction |
| Product features | Incentives, amplification, filtering, linearization, transformations, one-in-one, with a modem replacing multiple meters; built-in sensor sensitivity and multipointing, with the change of sensors only to change parameters without having to change hardware; programmable filters and traps, with a strong interference to stabilize readings in the environment; peak capture and high-speed sampling, with a balance between static Accuracy and dynamic measurements; four-end isolation, with Variable frequency drive, no interference with server co-location installation |
Product selection
VISCON-TR-100| Code | Number of channels |
|---|---|
| C1 | Single channel (Standard) |
| C2 | Dual Channels |
| C3 | Four-channels (carded case) |
| Code | Compatible sensors |
|---|---|
| S1 | Responsive bridge (called gravity/power/twirl) |
| S2 | mV output pressure sensor |
| S3 | RTD / Thermocouple |
| S4 | Ether / LVDT |
| S5 | Frequency / Turn speed |
| Code | Excitation method |
|---|---|
| E1 | Bridge pressure 5V / 10V programmable |
| E2 | Constant flow 1mA / 2mA |
| E3 | E1 + E2 switchable (Standard) |
| Code | Output signal |
|---|---|
| O1 | 4–20mA (Standard) |
| O2 | 0~10V / 1~5V |
| O3 | RS485(Modbus-RTU) |
| O4 | 4–20mA + RS485 + Alarm Touch |
| Code | Accuracy class |
|---|---|
| A1 | ±0.05%FS (Standard) |
| A2 | ±0.1%FS |
| A3 | ±0.02%FS (high Accuracy, order) |
| Code | Sampling speed |
|---|---|
| R1 | 10 sec/s |
| R2 | 100 sec/ sec (Standard) |
| R3 | 1000 sec/s (dynamic measurements) |
| Code | Special function |
|---|---|
| F1 | Basic type (magnification + transformation) |
| F2 | F1 + multipoint linear calibration |
| F3 | F2 + Peak/Valve maintained |
| F4 | F3 + Peak capture and decorate |
| Code | Structure with Display |
|---|---|
| M1 | DIN rail 22.5mm No display |
| M2 | DIN rail + 4 LED Display |
| M3 | Boxes (multi-channel centralized) |