Smart temperature adapterClick on the picture to zoom in.
PRODUCT SPECIFICATIONS
VISCON-TT-200
Smart temperature adapter
Smart temperature adapter, smart temperature adapter
01
Classification: Smart temperature adapter
02
Check configuration based on field work
TECHNICAL SPECIFICATIONS
Technical specifications
Check the specifications against your operating conditions and use the selection tables to confirm your order configuration.
View selection tables ↓| Model | VISCON-TT-200 |
|---|---|
| Product function | Locally convert RTD, thermocouple, mV to standard, 4–20mA, and superimpose HART digital communications; connect directly with DCS, PLC analogue input cards to compensate for the transmission of the conduits and the weak signals at long distances |
| Input type | RTD Pt100 / Pt1000 / Pt10 / Cu50 / Cu100 / Cu53 / Ni1000 (second, third, four-wire); thermocouple K / E / J / T / N / S / R / B / WRe3-WRe25; straight mV -10–+100mV; electrical 0–400Ω, 0–4000Ω |
| Measurement range | RTD -200–+850℃ (Pressed) sensor type); thermocouple -200–+1800℃ (Pressed) sensor type, B Type 600–1800℃); range high and low limits Free to set any range, minimum range 20℃ |
| Measurement accuracy | ±0.1%FS (standard); optional ±0.05%FS or ±0.2%FS; RTD three-wire pilot-wire electrical resistance automatic compensation, range 0–20Ω |
| Cold junction compensation | Internal Pt1000 cold end sensors to compensate for errors ±0.5℃; Optional external cold end (estate point or Temperature bath) to improve the accuracy of measurements of precious metal dolls |
| Output signal | Two-wire 4–20mA, superseding HART 7 digital signal; load resistance 0–600Ω (electricity 24V); output can be set for linear, open or temperature direct output |
| Power supply | DC 12–36V two-wire loop power (backway with output); four-wire DC 20–35V independent power supply; with reverse connection Overvoltage protection |
| Open-circuit detection | Sensor output programmable when cut off or short-circuited: Upspray 21.0mA, Downspray 3.6mA, keep final value selected; can be driven simultaneously Alarm Contact |
| Isolation performance | Four-wire quarantine: Input-output-triple-source quarantine, isolation voltage 1500VAC/1min; two-wire is separated between input and circuit 500VAC |
| Response time | ≤1s (at 63% step change); damping time 0–60s may be set to contain output vibration caused by media fluctuations |
| Display unit | Optional 4 bit LCD on the surface, alternating display temperature and current percentage; resolution 0.1℃ |
| Construction | Type DIN rail 35mm DIN rail thick 22.5mm; field type IP67 |
| Process connection | M20×1.5, G½, 1/2NPT Thread; or directly installed in RTD / Thermocouple Waterproof junction box (consorting) |
| Explosion protection | Intrinsically safe type Ex ia II C T4–T6 (must be associated equipment); field optional flameproof Ex d II C T6; Flameproof cavity separated from Intrinsically safe cavity |
| Operating environment | Temperature -40–+85℃ (electronic components), relative humidity ≤95%RH; in situ shell -40–+70℃ |
| Overall dimensions | DIN rail 22.5 × 110 × 118mm; field Φ110 × High 120mm (excluding interfaces) |
| Instrument weight | DIN rail 0.18kg; field 1.1kg |
| Applicable standards | IEC 60751 (industrial platinum RTD) / IEC 60584 (thermocouple) / GB/T 28473 / HART 7 communication protocols / GB 3836.1, GB 3836.4 (explosive type) |
| Typical applications | Pyramids for petrochemical, chemical, electrical, metallurgical devices, reaction plume, piping temperature measurements; matching with DCS temperature input cards, or replacing the old mV direct-link long-range compensation guide programme |
| Product features | Typical sensor type, with a small range of spare parts; HART Configuration Range Sensor type can be remotely modified; Three-wire wiring autocompensation to eliminate long-wire error; Open-circuit failure direction programmable to allow for chain logic; DIN rail the same circuit platform as the field model |
Product selection
VISCON-TT-200| Code | Input type |
|---|---|
| R1 | Pt100 Three-wire |
| R2 | Pt100 Four-wire |
| R3 | Pt1000 II/III Four-wire |
| R4 | Cu50 / Cu100 / Cu53 |
| T1 | Type thermocouple K |
| T2 | Thermocouple K/E/J/T general |
| T3 | Thermocouple S/R/B Precious metals |
| U1 | mV / Ω Unable Input (All Sensor type) |
| Code | Measurement range |
|---|---|
| A1 | -50~+200℃ |
| A2 | 0~+400℃ |
| A3 | 0~+600℃ |
| A4 | 0~+1000℃ |
| A5 | 0~+1300℃ |
| A6 | 0~+1800℃ |
| A7 | Special Range (Specify when ordering High and low limits) |
| Code | Accuracy class |
|---|---|
| P1 | ±0.1%FS (Standard) |
| P2 | ±0.05%FS |
| P3 | ±0.2%FS (Economy type) |
| Code | Output and Communications |
|---|---|
| O1 | 4–20mA Two-wire |
| O2 | 4–20mA + HART (Standard) |
| O3 | 4–20mA + HART + on site LCD Display |
| O4 | 4~20mA + RS485 Modbus RTU |
| Code | Construction |
|---|---|
| S1 | DIN rail 22.5mm 35mm DIN rail |
| S2 | On-site integrated aluminium shell, IP67 |
| S3 | Field belt LCD display IP67 |
| S4 | Four-wire quarantine (triple end isolation 1500VAC) |
| Code | Process connection |
|---|---|
| C1 | M20×1.5 Thread |
| C2 | G½ Thread |
| C3 | 1/2NPT Thread |
| C4 | RTD / Thermocouple Junction box (no Process connection) |
| Code | Explosion protection type |
|---|---|
| E1 | Non-Ex |
| E2 | Intrinsically safe Ex ia II C T4 |
| E3 | Flameproof Ex d II C T6 (field type) |
| E4 | Intrinsically safe type + with a separation fence (package of supplies) |
| Code | Additional functions |
|---|---|
| F1 | Basic (no additional) type |
| F2 | In situ LCD Display |
| F3 | Open-circuit alarm relay output |
| F4 | HART configuration + + self-diagnostic |
Confirm specifications and ordering options
Contact us with the measurement target, operating conditions, and installation requirements to confirm your configuration.
Contact us