Insertion typeClick on the picture to zoom in.

PRODUCT SPECIFICATIONS

FLUME-TM-100

Thermal gas mass flow meters . Insertion

Thermal gas mass flow meters, insert configuration. Thermal diffusion principles, gas mass flow measurements,

01

Classification: Thermal gas mass flow meter

02

Structure form: Insertion

⁇ Return to thermal gas mass flow meter classification

TECHNICAL SPECIFICATIONS

Technical specifications

FLUME-TM-100

Check the specifications against your operating conditions and use the selection tables to confirm your order configuration.

View selection tables ↓
ModelFLUME-TM-100
Nominal pipe sizeDN80~DN2000
Measurement principleThermal diffusion (stable temperature differentials, diptunium electrical resistance probes measuring temperature differentials, directly measuring gas mass flow)
Measured mediumGases such as air, nitrogen gas, gas, gas, flue gas, hydrogen gas (including small amounts of dust)
Accuracy class±1.0% (optional ±1.5%)
Repeatability±0.5%
Turndown ratio100:1
Flow velocity range1–60 Nm/s (Performance)
Process medium temperature-20~+350℃
Ambient temperature-25~+55℃
Operating pressure1.0MPa、1.6MPa、2.5MPa、4.0MPa、6.3MPa
Sensor material304 stainless steel / 316L stainless steel (probe 316L, inner platinum resistance)
Probe typeStandard Insert a spot / an online plug-in spot (with a ball valve, unstoppable to unload)
MountingPipe opening Insertion, Insertion depth Adjustable, support horizontal/vertical pipe
Straight pipe length requirements10D, 5D
ConnectionFlanged connection, Threaded connection, card connections
Display typeLCD Local display immediate/ Totalized flow (Optional No display)
Output signal(4–20) mA, HART, RS485 (Modbus), Pulse
Power supply24V DC、220V AC
Explosion protection markingEx ia IIC T4 (intrinsically safe), Ex d IIC T6 (Flameproof)
Ingress protectionIP65 (optional IP67)
Electrical connectionM20×1.5
Pressure lossNeglectable (uncontrolled fluids without loss of additional pressure)
Flow unitsNm³/h, m³/h, kg/h, t/h (toggle)

Product selection

FLUME-TM-100
Size and flow ranges
CodeNominal size (mm)Measurement range (Nm³/h)
80DN8018~1086
100DN10028~1696
125DN12544~2651
150DN15064~3817
200DN200113~6786
250DN250177~10603
300DN300254~15268
400DN400452~27143
500DN500707~42412
600DN6001018~61073
800DN8001810~108573
1000DN10002827~169646
1200DN12004072~244290
1400DN14005542~332506
1600DN16007238~434294
2000DN200011310~678584
Pressure rating
CodePressure rating
P11.0 MPa
P21.6 MPa
P32.5 MPa
P44.0 MPa
P56.3 MPa
Sensor material
CodeSensor material
B1304 Stainless steel
B2316L Stainless steel
Probe type
CodeProbe type
K1Standard insert a probe
K2Online plug-in.
Accuracy class
CodeAccuracy class
E1±1.0%
E2±1.5%
Process medium temperature
CodeProcess medium temperature
T1-20~120℃
T2≤200℃
T3≤350℃
Connection
CodeConnection
C1Flanged connection
C2Threaded connection
C3Cassette Connection
Display type
CodeDisplay type
G1No display
G2LCD Local display
Power supply
CodePower supply
D124V DC
D2220V AC
Signal output
CodeSignal output
F1(4~20)mA
F2(4~20)mA + HART
F3RS485(Modbus)
Explosion protection marking
CodeExplosion protection marking
U0Non-Ex
U1Ex ia IIC T4 (Intrinsically safe)
U2Ex d IIC T6 (Flameproof)

Confirm specifications and ordering options

Contact us with the measurement target, operating conditions, and installation requirements to confirm your configuration.

Contact us
FLUME-TM-100 Thermal Mass Gas Flowmeter