SectorClick on the picture to zoom in.

PRODUCT SPECIFICATIONS

FLUME-US-150

Hypersonic flow meters .

Hypersonic flow meters, sector configuration. Select the appropriate measurement and installation configuration in conjunction with the field condition.

01

Classification: ultrasound flow count

02

Structure form: paragraphs

⁇ Return ultrasound flow count classification

TECHNICAL SPECIFICATIONS

Technical specifications

FLUME-US-150

Check the specifications against your operating conditions and use the selection tables to confirm your order configuration.

View selection tables ↓
ModelFLUME-US-150
Nominal pipe sizeDN15~DN300
Measurement principleTransit-time ultrasonic measurement
Measuring tube material304 / 316 Stainless steel
ConnectionFlanged connection (GB/T 9119), Thread, Optional
LinerGlossy-free inner wall, free of pressure
Process medium temperatureStandard type: −40 to +90 °C. High-temperature type: −40 to +150 °C.
Ambient temperatureConverter: −20 to +60 °C
Operating pressureDN15–DN300 1.6MPa / 2.5MPa / 4.0MPa (specify when ordering)
Accuracy class0.5 (0.5–5m/s), optional 1.0
Flow velocity range0–32m/s (recommended 0.5–5m/s)
Output signal(4~20) mA electric current, pulse, RS485, HART, High and low limits Alarm (total isolation)
DisplayInstantaneous flow, flow speed, positive and reverse aggregate, Alarm Display
MountingFlange installation, plant marked, ready to be installed
Ingress protectionIP65 / IP68
CommunicationRS485 (Modbus protocol), HART
Explosion protection markingEx d IIB T6 Gb
Power consumption≤15W
Power supply220V AC 50Hz、24V DC

Product selection

FLUME-US-150
Size and flow ranges
CodeNominal size (mm)Measurement range (m3/h)
15DN150.32~6.38
20DN200.57~11.30
25DN250.88~17.66
32DN321.45~28.94
40DN402.26~45.22
50DN503.35~70.65
65DN655.97~119.40
80DN809.04~180.86
100DN10014.13~282.60
125DN12522.08~441.56
150DN15031.79~635.85
200DN20056.52~1130.40
250DN25088.31~1766.25
300DN300127.17~2543.40
Pressure rating
CodePressure rating
P21.0 MPa
P31.6 MPa
P42.5 MPa
P54.0 MPa
Measuring tube material
CodeMeasuring tube material
B2304 Stainless steel
B3316 Stainless steel
Connection
CodeConnection
L1Flanged connection (GB/T 9119)
L2Threaded connection (≤DN50)
L3Clamp connection (sanitary type)
Accuracy class
CodeAccuracy class
E1Level 1.0
E2Level 0.5
Signal output
CodeSignal output
F1(4~20) mA, pulse, RS485 (Modbus)
F2(4~20) mA, pulse, RS485 (Modbus), HART
Power supply
CodePower supply
D1220V AC 50Hz
D224V DC
Explosion protection marking
CodeExplosion protection marking
U1It's blastproof.
U2No blast-proof.

Confirm specifications and ordering options

Contact us with the measurement target, operating conditions, and installation requirements to confirm your configuration.

Contact us
FLUME-US-150 Ultrasonic Flowmeter (In-line)