ContinuousClick on the picture to zoom in.
PRODUCT SPECIFICATIONS
LISEN-FB-100
Magnetic floats, liquids.
Magnetic floats, continuous configuration. Magnetic float switches, simple and reliable structure.
01
Classification: Magnetic Float Liquefied Count
02
Structure form: continuous
TECHNICAL SPECIFICATIONS
Technical specifications
Check the specifications against your operating conditions and use the selection tables to confirm your order configuration.
View selection tables ↓| Model | LISEN-FB-100 |
|---|---|
| Measurement principle | Magnetic float with Level floating, Magnetostrictive / Reed switch array continuous detection Level |
| Measurement type | Level continuing measurements + 4–20mA apogee |
| Measurement range | 300–3000mm (Insertion depth) |
| Measurement accuracy | ±1mm (magnetic) / ±5mm (Ring Array) |
| Resolution | 0.1mm (magnetic) |
| Medium density | ≥0.5g/cm3 |
| Medium viscosity | ≤0.3Pa·s |
| Operating pressure | -0.1–2.5MPa (Land-pressure jars up to constant pressure) |
| Process medium temperature | -40–+120℃ (hot float to +200℃) |
| Tube material | 304 / 316L Stainless steel pipe (Has/ titanium Optional) |
| Float material | 316L stainless steel / PTFE covered (Optional) |
| Float diameter | φ52 / φ65 (Low-density medium with big floats) |
| Connection | Top DN50/DN80 flange Install / M20×1.5 Thread |
| Output signal | 4–20mA (DC) two-wire / RS485 (MODBUS) Optional |
| Power supply | 24VDC (Two-wire Loop power) |
| Display type | 4 LCD / LED Display |
| Ingress protection | IP65 / IP67 |
| Explosion protection marking | Ex d II C T6 Gb / Ex ia II C T4 Ga (Optional) |
| Applicable standards | JB/T 12083 / HG/T 21584 |
| Suitable media | Water, oils, acids and alkalis; storage tanks, water tanks, response pads Level continuous monitoring and long transmission |
Product selection
LISEN-FB-100| Code | Sensor Type |
|---|---|
| S1 | Type magnetostrictive (±1mm height Accuracy) |
| S2 | Reed switch Array (Economy type) |
| Code | Insertion depth (measurement range) |
|---|---|
| L1 | 300~1000mm |
| L2 | 1000~2000mm |
| L3 | 2000~3000mm |
| Code | Tube material |
|---|---|
| M1 | 304 Stainless steel |
| M2 | 316L Stainless steel |
| M3 | Hastelloy C276 |
| M4 | Titanium alloy Ti |
| Code | Float material / size |
|---|---|
| B1 | 316L φ52 (Standard) |
| B2 | 316L φ65 (Low density medium) |
| B3 | PTFE complete (strong corrosive) |
| Code | Connection |
|---|---|
| F1 | Top DN50 Flange |
| F2 | Top DN80 Flange |
| F3 | M20×1.5 Thread |
| Code | Output signal |
|---|---|
| O1 | 4–20mA Two-wire (Standard) |
| O2 | 4~20mA + HART |
| O3 | RS485(MODBUS-RTU) |
| Code | Display type |
|---|---|
| D1 | No display |
| D2 | 4 LCD Display |
| Code | Explosion protection marking |
|---|---|
| X1 | Non-Ex |
| X2 | Flameproof Ex d II C T6 Gb |
| X3 | Intrinsically safe Ex ia II C T4 Ga |
Confirm specifications and ordering options
Contact us with the measurement target, operating conditions, and installation requirements to confirm your configuration.
Contact us