StandardClick on the picture to zoom in.

PRODUCT SPECIFICATIONS

LISEN-LT-100

Liquid-bit transducer . Standard

LPG, standard configuration. Input LTP

01

Classification: Liquefied Transmitter

02

Structure form: criteria

⁇ Return liquid-place transducer class

TECHNICAL SPECIFICATIONS

Technical specifications

LISEN-LT-100

Check the specifications against your operating conditions and use the selection tables to confirm your order configuration.

View selection tables ↓
ModelLISEN-LT-100
Measurement principleSilent pressure formula: transmitter input fluid floor P = old gh converted output Level height
Measurement range0–1mH2O – 0–200mH2O (ordered range, turndown ratio 10:1)
Measurement accuracy±0.25%FS / ±0.5%FS (Optional)
Long-term stability±0.2%FS /year
Overload capacity1.5 multiple range instant 2 clean
Process medium temperature-20–+70℃ (high-temperature type to +85℃)
Ambient temperature-20~+70℃
Operating pressureConstant pressure / micropressure open container (prompt static pressure Range)
Isolation diaphragm316L Stainless steel (polytous/ tantalum film Optional)
Probe housing304 stainless steel (φ27×130mm Standard)
Vented cablePolyurethane (PUR) conductor shielded cable standard 10m (optional 5–200m)
Output signal4–20mA two-wire (RS485 Optional)
Power supply12–36VDC (standard 24VDC, Loop power)
Load resistance≤(U-12V)/0.02A
Ingress protectionIP68
Electrical connectionDirect Line / junction box (IP65)
Explosion protection markingEx ia II C T4 Ga Intrinsically safe (Optional)
Applicable standardsGB/T 28474 / JB/T 12597 / JJG 882
Suitable mediaMeasurement of Level open containers such as water, sewage, groundwater, reservoirs, reservoirs, oil tanks, water tanks

Product selection

LISEN-LT-100
Measurement type
CodeMeasurement type
T1Input Level (Standard)
T2Input level + temperature (Pt100)
Measuring span (mH2O)
CodeMeasuring span (mH2O)
L10~1 / 0~5
L20~10 / 0~20
L30~50 / 0~100
L40–200 (Specify when ordering)
Accuracy class
CodeAccuracy class
E1±0.5%FS
E2±0.25%FS (Standard)
Isolation diaphragm material
CodeIsolation diaphragm material
M1316L Stainless steel (Standard)
M2Ceramic (Al2O3)
M3Tantalum film (strong corrosive)
Cable Length
CodeCable Length
C15m / 10m (Standard)
C220m / 30m
C350m / 100m (Specify when ordering)
Output signal
CodeOutput signal
O14–20mA Two-wire (Standard)
O2RS485(MODBUS-RTU)
O34~20mA + HART
Display type
CodeDisplay type
D1No display (Standard)
D2LCD Local display
Explosion protection marking
CodeExplosion protection marking
X1Non-Ex
X2Intrinsically safe Ex ia II C T4 Ga

Confirm specifications and ordering options

Contact us with the measurement target, operating conditions, and installation requirements to confirm your configuration.

Contact us