CableClick on the picture to zoom in.
PRODUCT SPECIFICATIONS
LISEN-RA-300
Convey radar position index. Cable.
Convey radar position counter, cable configuration. Convey radar, application of low-media constants and small tanks
01
Classification: Guided radar positionometer
02
Structure form: cable
TECHNICAL SPECIFICATIONS
Technical specifications
Check the specifications against your operating conditions and use the selection tables to confirm your order configuration.
View selection tables ↓| Model | LISEN-RA-300 |
|---|---|
| Measurement principle | TDR time-area reflection: microwave Pulse spreads along the cable, mirrors the surface of the medium and calculates the position by time difference |
| Measurement type | Level (L) / Solid particle feed level (S) / Interface (I) |
| Measurement range | 0.5–30m (Cable length optional 3/6/10/15/20/30m) |
| Measurement accuracy | ±5mm or ±0.1%FS (takes big) |
| Resolution | 1mm |
| Repeatability | ±3mm |
| Dielectric constant | ε r ≥1.6 (Purpose level) ≥1.5) |
| Operating pressure | -0.1~2.5MPa |
| Process medium temperature | -40–+150℃ (high-temperature type to +200℃) |
| Guided-wave probe cable material | 316L stainless steel wire rope (φ4, PTFE cover Optional) |
| Process connection | DN80 / DN100 flange (PN1.0–2.5) / G1½ Thread |
| Weight | Bottom φ40 Stainless steel with a hammer (floating) |
| Output signal | 4–20mA (DC) +HART two-wire / RS485 (MODBUS) Optional |
| Power supply | 16–36VDC (standard 24VDC, Two-wire) |
| Display type | 4 bit LCD LCD display + Returning curve site to check, press key/magnetic pen |
| Damping time | 0–40s Configurable |
| Dead zone | Top dead zone ≤0.5m |
| Ingress protection | IP66 / IP67 |
| Explosion protection marking | Ex d II C T6 Gb / Ex ia II C T4 Ga (Optional) |
| Applicable standards | GB/T 28474 / IEC 61508 (SIL2 optional) / HART 7 |
| Suitable media | Water, sewage, alkaline, oils; large Range tanks, silos, silos, powder/particle levels, etc. |
Product selection
LISEN-RA-300| Code | Measurement function |
|---|---|
| T1 | Level (L) |
| T2 | Solid particle feed position (S) |
| T3 | Liquid - liquid interface (I) |
| Code | Wire length (Measurement range) |
|---|---|
| L1 | 3m / 6m |
| L2 | 10m / 15m |
| L3 | 20m / 30m (Specify when ordering) |
| Code | Accuracy class |
|---|---|
| E1 | ±10mm |
| E2 | ±5mm (Standard) |
| Code | Guided-wave probe cable material |
|---|---|
| M1 | 316L Stainless steel wire rope (Standard) |
| M2 | 316L + PTFE cover |
| M3 | Hastelloy C276 |
| Code | Process connection |
|---|---|
| F1 | G1½ Thread |
| F2 | DN80 Flange |
| F3 | DN100 Flange |
| Code | Output signal |
|---|---|
| O1 | 4–20mA + HART (Standard) |
| O2 | RS485(MODBUS-RTU) |
| Code | Explosion protection marking |
|---|---|
| X1 | Non-Ex |
| X2 | Flameproof Ex d II C T6 Gb |
| X3 | Intrinsically safe Ex ia II C T4 Ga |
Confirm specifications and ordering options
Contact us with the measurement target, operating conditions, and installation requirements to confirm your configuration.
Contact us