CableClick on the picture to zoom in.

PRODUCT SPECIFICATIONS

LISEN-RA-300

Convey radar position index. Cable.

Convey radar position counter, cable configuration. Convey radar, application of low-media constants and small tanks

01

Classification: Guided radar positionometer

02

Structure form: cable

⁇ Return to the guide radar position index classification

TECHNICAL SPECIFICATIONS

Technical specifications

LISEN-RA-300

Check the specifications against your operating conditions and use the selection tables to confirm your order configuration.

View selection tables ↓
ModelLISEN-RA-300
Measurement principleTDR time-area reflection: microwave Pulse spreads along the cable, mirrors the surface of the medium and calculates the position by time difference
Measurement typeLevel (L) / Solid particle feed level (S) / Interface (I)
Measurement range0.5–30m (Cable length optional 3/6/10/15/20/30m)
Measurement accuracy±5mm or ±0.1%FS (takes big)
Resolution1mm
Repeatability±3mm
Dielectric constantε r ≥1.6 (Purpose level) ≥1.5)
Operating pressure-0.1~2.5MPa
Process medium temperature-40–+150℃ (high-temperature type to +200℃)
Guided-wave probe cable material316L stainless steel wire rope (φ4, PTFE cover Optional)
Process connectionDN80 / DN100 flange (PN1.0–2.5) / G1½ Thread
WeightBottom φ40 Stainless steel with a hammer (floating)
Output signal4–20mA (DC) +HART two-wire / RS485 (MODBUS) Optional
Power supply16–36VDC (standard 24VDC, Two-wire)
Display type4 bit LCD LCD display + Returning curve site to check, press key/magnetic pen
Damping time0–40s Configurable
Dead zoneTop dead zone ≤0.5m
Ingress protectionIP66 / IP67
Explosion protection markingEx d II C T6 Gb / Ex ia II C T4 Ga (Optional)
Applicable standardsGB/T 28474 / IEC 61508 (SIL2 optional) / HART 7
Suitable mediaWater, sewage, alkaline, oils; large Range tanks, silos, silos, powder/particle levels, etc.

Product selection

LISEN-RA-300
Measurement function
CodeMeasurement function
T1Level (L)
T2Solid particle feed position (S)
T3Liquid - liquid interface (I)
Wire length (Measurement range)
CodeWire length (Measurement range)
L13m / 6m
L210m / 15m
L320m / 30m (Specify when ordering)
Accuracy class
CodeAccuracy class
E1±10mm
E2±5mm (Standard)
Guided-wave probe cable material
CodeGuided-wave probe cable material
M1316L Stainless steel wire rope (Standard)
M2316L + PTFE cover
M3Hastelloy C276
Process connection
CodeProcess connection
F1G1½ Thread
F2DN80 Flange
F3DN100 Flange
Output signal
CodeOutput signal
O14–20mA + HART (Standard)
O2RS485(MODBUS-RTU)
Explosion protection marking
CodeExplosion protection marking
X1Non-Ex
X2Flameproof Ex d II C T6 Gb
X3Intrinsically safe Ex ia II C T4 Ga

Confirm specifications and ordering options

Contact us with the measurement target, operating conditions, and installation requirements to confirm your configuration.

Contact us
LISEN-RA-300 Guided Wave Radar Level Transmitter (Cable type)