Great.Click on the picture to zoom in.
PRODUCT SPECIFICATIONS
LISEN-TF-200
Sound fork-style position controller.
Sound fork position controller, stick configuration. Sound fork position switches, respond quickly
01
Classification: Sound fork position controller
02
Structure form: Great
TECHNICAL SPECIFICATIONS
Technical specifications
Check the specifications against your operating conditions and use the selection tables to confirm your order configuration.
View selection tables ↓| Model | LISEN-TF-200 |
|---|---|
| Measurement principle | Fork vibration: voltage-incentive acoustic fork at the resonance frequency vibration, frequency/ amplitude changes after the fork immersed in the medium, by detection circuit output switch |
| Structural characteristics | Forklifts are extended by rigid extension rods, and forklifts go deep into the tank to measure points, avoiding the insulation/plugs/can wall-mounted Agitation zone |
| Switching action | Point switch output (high or low, field dialling/key setting) |
| Extension rod length | Standard 300mm, optional 500 / 800 / 1000 / 1500 / 2000mm (Specify when ordering) |
| Suitable medium density | Liquid ≥0.5g/cm3 / Solid powder ≥0.1g/cm3 |
| Medium viscosity | ≤10000mm2/s (extended rod surface smooth, suitable for viscous medium) |
| Repeatability | ±1mm |
| Delay Settings | 0–10s Adjustable |
| Process medium temperature | -40–+150℃ (high-temperature type to +200℃) |
| Ambient temperature | -40~+70℃ |
| Operating pressure | Common pressure –2.5MPa (common pressure thick cans/open pool dominated) |
| Tuning fork / extension rod material | 316L stainless steel (Hass C276 / PTFE cover Optional) |
| Tuning fork finish | Standard Ra≤3.2μm / PTFE corruption coating (Optional) |
| Process connection | DN80 / DN100 flange / G1½ Thread / Side-to-side |
| Support Mode | Single-end suspension fixed (≤1m) / Adding guidance support rings (>1m) |
| Output signal | Voltage-free dry contact SPDT (5A/250VAC)/ NAMUR Intrinsically safe (Optional) |
| Power supply | 24VDC / 220VAC (Optional) |
| Status indicator | LED tri-state instruction (power/ Alarm / normal) |
| Ingress protection | IP65 / IP66 |
| Explosion protection marking | Ex d II C T6 Gb flameproof / Ex ia II C T4 Ga Intrinsically safe (Optional) |
| Applicable standards | GB/T 28474 / JB/T 12597 / GB 3836.1 |
| Suitable media | Magnificent liquids, slurry, slurry, particulate powder; thick wall-reactors with a temperature layer/set, deep pool, pit |
| Typical applications | Level Alarm, pit/water collection well height Level, deep pond / oxidized ditch Level chain, mixer cans avoiding limit control of the mixer oar |
Product selection
LISEN-TF-200| Code | Extension rod length |
|---|---|
| L1 | 300mm (Standard) |
| L2 | 500 / 800mm |
| L3 | 1000 / 1500mm |
| L4 | 2000mm (Specify when ordering, need to be directed to support) |
| Code | Process connection |
|---|---|
| F1 | DN80 Flange |
| F2 | DN100 Flange |
| F3 | G1½ Thread |
| F4 | Side-to-side assembly (ground pit/opener pool) |
| Code | Support Mode |
|---|---|
| S1 | Single-end arm fixed (≤1m, Standard) |
| S2 | Adding >1m Guided Support Rings |
| Code | Switching action |
|---|---|
| A1 | High Alarm (full) |
| A2 | Low Alarm (negative empty) |
| Code | Tuning fork / extension rod material |
|---|---|
| M1 | 316L Stainless steel (Standard) |
| M2 | PTFE wrapping (strength corrosive/adhesive) |
| M3 | Hastelloy C276 |
| Code | Output signal |
|---|---|
| O1 | Voltage-free dry contact SPDT (Standard) |
| O2 | NAMUR Intrinsically safe signal (with security fence) |
| Code | Power supply |
|---|---|
| S1 | 24VDC (Standard) |
| S2 | 220VAC |
| Code | Explosion protection marking |
|---|---|
| X1 | Non-Ex |
| X2 | Flameproof Ex d II C T6 Gb |
| X3 | Intrinsically safe Ex ia II C T4 Ga |
Confirm specifications and ordering options
Contact us with the measurement target, operating conditions, and installation requirements to confirm your configuration.
Contact us