Fine.Click on the picture to zoom in.
PRODUCT SPECIFICATIONS
PRETRAN-DM-100
Smart silica pressure transmitter...
Smart-spread silicon pressure transmitter, fine configuration. Spread silicon sensors, high value.
01
Classification: Smart diffusion of silicon pressure transmitters
02
Structure form: precision
TECHNICAL SPECIFICATIONS
Technical specifications
Check the specifications against your operating conditions and use the selection tables to confirm your order configuration.
View selection tables ↓| Model | PRETRAN-DM-100 |
|---|---|
| Measurement principle | Diffused silicon piezoresistive core + digital signal processing (smart) |
| Measurement type | Gauge pressure (G) / absolute pressure (A) / negative pressure (S) |
| Measurement range | 0–10kPa to 0–60MPa (turndown ratio 10:1 Adjustable) |
| Accuracy class | ±0.25% / ±0.5% (Optional) |
| Overload capacity | 2 multiple Full scale (in a moment) |
| Output signal | 4–20mA (DC) two-wire / 4–20mA+HART / RS485 (MODBUS) Optional |
| Power supply | 12–36VDC (standard 24VDC), Two-wire Loop power |
| Load capacity | (supply voltage -12V) / 0.02A, max 600Ω |
| Sensor core | 316L Isolation diaphragm Diffused silicon core, all welded oil wraps |
| Process connection | M20×1.5 / G1/2 / 1/2NPT (Male thread) |
| Display type | 3½-digit LED or optional 4-digit LCD. On-site zero and span adjustment via buttons. |
| Damping time | 0–15s Configurable |
| Stability | ±0.2% /year |
| Process medium temperature | -40–+85℃ (standard) / -40–+125℃ (High-temperature type Optional) |
| Ambient temperature | -40~+85℃ |
| Relative Humidity | 0–95%RH (Non-condensing) |
| Ingress and explosion protection | IP65; Ex d II C T6 Gb / Ex ia II C T4 Ga (Optional) |
| Electrical connection | Hirschmann Hersmann connection / M20×1.5 cable sealed |
| Applicable standards | GB/T 17614 / IEC 61010 / HART 7 |
| Suitable media | Liquids, gases, vapours (compatible 316L), fine-sized for space-limited pumps, hydraulics, air pressure equipment |
Product selection
PRETRAN-DM-100| Code | Measurement type |
|---|---|
| T1 | Gauge pressure (G) |
| T2 | Absolute pressure (A) |
| T3 | Negative pressure (S) -100kPa–0 |
| Code | Range options |
|---|---|
| R1 | 0~10kPa~0~100kPa |
| R2 | 0~100kPa~0~1MPa |
| R3 | 0~1MPa~0~10MPa |
| R4 | 0~10MPa~0~60MPa |
| Code | Accuracy class |
|---|---|
| E1 | ±0.5%FS |
| E2 | ±0.25%FS |
| Code | Output signal |
|---|---|
| O1 | 4–20mA Two-wire (Standard) |
| O2 | 4~20mA + HART |
| O3 | RS485 (MODBUS-RTU) Three-wire |
| Code | Isolation diaphragm material |
|---|---|
| M1 | 316L Stainless steel |
| M2 | Hastelloy C276 |
| M3 | Tantalum Ta (strong corrosive) |
| Code | Process connection |
|---|---|
| J1 | M20×1.5 Male thread |
| J2 | G1/2 Male thread |
| J3 | 1/2NPT Male thread |
| Code | Display type |
|---|---|
| L1 | No display (Standard) |
| L2 | 3½ bit LED digit Display |
| L3 | 4 bit LCD display + Key change |
| Code | Explosion protection marking |
|---|---|
| X1 | Non-Ex |
| X2 | Flameproof Ex d II C T6 Gb |
| X3 | Intrinsically safe Ex ia II C T4 Ga |
Confirm specifications and ordering options
Contact us with the measurement target, operating conditions, and installation requirements to confirm your configuration.
Contact us