Waterproof.Click on the picture to zoom in.
PRODUCT SPECIFICATIONS
PRETRAN-DM-150
Smart-silli-pressure transmitters. Waterproof.
Smart-spread silicon pressure transmitter, waterproof configuration. Spread silicon sensors, high value.
01
Classification: Smart diffusion of silicon pressure transmitters
02
Structure form: water protection
TECHNICAL SPECIFICATIONS
Technical specifications
Check the specifications against your operating conditions and use the selection tables to confirm your order configuration.
View selection tables ↓| Model | PRETRAN-DM-150 |
|---|---|
| Measurement principle | Diffused silicon piezoresistive core + digital signal processing (smart) |
| Measurement type | Gauge pressure (G) / Input level (L) |
| Measurement range | 0–10kPa to 0–10MPa (turndown ratio 10:1 Adjustable) |
| Accuracy class | ±0.25% / ±0.5% (Optional) |
| Overload capacity | 2 multiple Full scale (in a moment) |
| Ingress protection | IP68 (all welding waterproof seals, long-term immersion) |
| Output signal | 4–20mA (DC) two-wire / 4–20mA+HART / RS485 Optional |
| Power supply | 12–36VDC (standard 24VDC), Two-wire Loop power |
| Load capacity | (supply voltage -12V) / 0.02A, max 600Ω |
| Sensor core | 316L isolation diaphragm diffused silicon core, double O loop + silicon cable sealed |
| Process connection | M20×1.5 male thread / Input G1DN25 hanged sediment hole |
| Cables | φ7.5 waterproof air cables (standard 5m/10m, maximum 100m) |
| Display type | 3½ bit LED digit display / 4 bit LCD (Optional) |
| Damping time | 0–15s Configurable |
| Stability | ±0.2% /year |
| Process medium temperature | 0–+70℃ (normal temperature) / -20–+85℃ (Low-temperature type Optional) |
| Ambient temperature | -40~+85℃ |
| Relative Humidity | 0–100%RH (Long-term underwater work) |
| Ingress and explosion protection | Ex d II C T6 Gb / Ex ia II C T4 Ga (Optional) |
| Electrical connection | Integrated waterproof cable straight out (no exposed end of line) |
| Applicable standards | GB/T 17614 / IEC 61010 / HART 7 |
| Suitable media | Water, sewage, oil; deep well water level, reservoir/river Level, tank input Level, etc. wet immersion |
Product selection
PRETRAN-DM-150| Code | Structural uses |
|---|---|
| S1 | Pressure type (with process interface M20×1.5) |
| S2 | Input type level (G1 sink + hung) |
| Code | Range options |
|---|---|
| R1 | 0~10kPa(1mH2O)~0~100kPa(10mH2O) |
| R2 | 0~100kPa~0~1MPa |
| R3 | 0~1MPa~0~10MPa |
| Code | Accuracy class |
|---|---|
| E1 | ±0.5%FS |
| E2 | ±0.25%FS |
| Code | Output signal |
|---|---|
| O1 | 4–20mA Two-wire (Standard) |
| O2 | 4~20mA + HART |
| O3 | RS485(MODBUS-RTU) |
| Code | Isolation diaphragm material |
|---|---|
| M1 | 316L Stainless steel |
| M2 | Hastelloy C276 |
| Code | Length of waterproof cables |
|---|---|
| C1 | 5m (Standard) |
| C2 | 10m |
| C3 | 20m / 50m / 100m (Specify when ordering) |
| Code | Display type |
|---|---|
| L1 | No display (Standard) |
| L2 | 3½ bit LED digit Display |
| L3 | 4 bit LCD display + Key change |
| Code | Explosion protection marking |
|---|---|
| X1 | Non-Ex |
| X2 | Flameproof Ex d II C T6 Gb |
| X3 | Intrinsically safe Ex ia II C T4 Ga |
Confirm specifications and ordering options
Contact us with the measurement target, operating conditions, and installation requirements to confirm your configuration.