IntegralClick on the picture to zoom in.

PRODUCT SPECIFICATIONS

FLUME-EM-100

· One-size-fits-all

EMP, One-Package. Based on the Faraday EMP, measure the volume of conductive liquid flow.

01

Classification: EMP

02

Structure form: One

⁇ Return to EMP classification

TECHNICAL SPECIFICATIONS

Technical specifications

FLUME-EM-100

Check the specifications against your operating conditions and use the selection tables to confirm your order configuration.

View selection tables ↓
ModelFLUME-EM-100
Nominal pipe sizeDN15~DN300
Liner materialPTFE / FEP (F46) / neoprene (CR) / polyurethane (PU) / PFA
ConnectionFlanged connection
Electrode material316L, Hastelloy C, Hastelloy B, titanium, tantalum, platinum-iridium alloy, or tungsten carbide-coated stainless steel
Housing materialPowder-coated carbon steel / 304 stainless steel / 316 stainless steel (select B1, B2, or B3)
Ambient temperatureSensor: −40 to +80 °C. Converter: −15 to +50 °C.
Process medium temperature≤150℃
Operating pressureDN15–DN300: 1.6 MPa (specify special requirements when ordering)
Accuracy classClass 0.5 at 0.5–5 m/s
CommunicationRS485 (Modbus protocol), HART
Load resistance≤750 Ω with 4–20 mA output
Medium conductivity≥5μS/cm
Flow velocity range0.5–10m/s (recommended 0.5–5m/s)
Display readingsInstantaneous flow, velocity, percentage, empty-pipe ratio, forward and reverse totals, and alarms
Ingress protectionIP65 / IP68
Explosion protection markingEx d IIB T6 Gb
Output signalFully isolated 4–20 mA, pulse, and high/low alarm outputs
Power consumption≤15W
Power supply220V AC 50Hz、24V DC

Product selection

FLUME-EM-100
Size and flow ranges
CodeNominal size (mm)Measurement range (m³/h)
15DN150.32~6.36
20DN200.57~11.30
25DN250.88~17.66
32DN321.45~28.94
40DN402.26~45.22
50DN503.35~70.65
65DN655.97~119.40
80DN809.04~180.86
100DN10014.13~282.60
125DN12522.08~441.56
150DN15031.79~635.85
200DN20056.52~1130.40
250DN25088.31~1766.25
300DN300127.17~2543.40
Pressure rating
CodePressure rating
P21.0 MPa
P31.6 MPa
P42.5 MPa
P54.0 MPa
Sensor material
CodeSensor material
B1Carbon steel
B2304 Stainless steel
B3316 Stainless steel
Liner material
CodeLiner material
C1PTFE (F4, ≤120℃)
C2FEP (F46, ≤120℃)
C3Neoprene (≤65℃)
C4Polyurethane rubber (≤40℃)
C5PFA (≤150℃, Vacuum resistance)
Electrode material
CodeElectrode material
K1316L
K2Hastelloy B
K3Hastelloy C
K4Titanium
K5Tantalum
K6Platinum-iridium alloy
K7Tungsten carbide-coated stainless steel
Accuracy class
CodeAccuracy class
E2Level 0.5
Construction
CodeConstruction
S1One (≤70℃)
Power supply
CodePower supply
D1220V AC 50Hz
D224V DC
Signal output
CodeSignal output
F1(4~20) mA, frequency, pulse, RS485 (Modbus)
F2(4~20) mA, frequency, pulse, HART
Explosion protection marking
CodeExplosion protection marking
U1It's blastproof.

Confirm specifications and ordering options

Contact us with the measurement target, operating conditions, and installation requirements to confirm your configuration.

Contact us
FLUME-EM-100 Electromagnetic Flowmeter