Insertion typeClick on the picture to zoom in.

PRODUCT SPECIFICATIONS

FLUME-EM-200

EMPLOYMENT .

EMP, insert configuration. Based on the Faraday method of electromagnetic induction, measure the volume of conductive fluid flow.

01

Classification: EMP

02

Structure form: Insertion

⁇ Return to EMP classification

TECHNICAL SPECIFICATIONS

Technical specifications

FLUME-EM-200

Check the specifications against your operating conditions and use the selection tables to confirm your order configuration.

View selection tables ↓
ModelFLUME-EM-200
Nominal pipe sizeDN150~DN1800
Liner material/ (Insertion lineless)
ConnectionFlanged connection, Threaded connection
Electrode material316L, Hastelloy C, titanium (Optional)
Housing material304 stainless steel / 316 Stainless steel (Optional)
Ambient temperature-20~60℃
Process medium temperature-10~70℃
Operating pressure0.25MPa~1.6MPa
Accuracy class±2.0%F.S (0.5~5)m/s
CommunicationRS485 (Modbus protocol)
Load resistance≤750 Ω with 4–20 mA output
Medium conductivity≥5μS/cm
Flow velocity range0.5–10m/s (recommended 0.5–5m/s)
Display readingsInstantaneous flow, flow speed, percentage, Alarm Display
Ingress protectionIP65
Explosion protection markingEx d IIB T6 Gb
Output signalTotal isolation (4–20mA electric current, Pulse)
Power consumption≤15W
Power supply24V DC

Product selection

FLUME-EM-200
Size and flow ranges
CodeNominal size (mm)Measurement range (m³/h)
150DN15031.79~635.85
200DN20056.52~1130.40
250DN25088.31~1766.25
300DN300127.17~2543.40
350DN350173.09~3461.85
400DN400226.08~4521.60
450DN450286.28~5725.55
500DN500353.43~7068.58
600DN600508.94~10178.76
700DN700692.72~13854.42
800DN800904.78~18095.57
900DN9001145.11~22902.21
1000DN10001413.72~28274.33
1200DN12002035.75~40715.04
1400DN14002770.88~55417.69
1600DN16003619.11~72382.29
1800DN18004580.44~91608.84
Pressure rating
CodePressure rating
P21.0 MPa
P31.6 MPa
Sensor material
CodeSensor material
B2304 Stainless steel
B3316 Stainless steel
Electrode material
CodeElectrode material
K1316L
K3Hastelloy C
K4Titanium
Accuracy class
CodeAccuracy class
E2Level 0.5
E4±2.0%F.S (Insertion)
Construction
CodeConstruction
S1One (≤70℃)
S2Fragmentation (≤150℃)
Power supply
CodePower supply
D224V DC
Signal output
CodeSignal output
F1(4~20) mA, frequency, pulse, RS485 (Modbus)
Explosion protection marking
CodeExplosion protection marking
U1It's blastproof.

Confirm specifications and ordering options

Contact us with the measurement target, operating conditions, and installation requirements to confirm your configuration.

Contact us
FLUME-EM-200 Electromagnetic Flowmeter