RemoteClick on the picture to zoom in.
PRODUCT SPECIFICATIONS
FLUME-EM-150
· EMP.
EMP, split configuration. Based on the Faraday electromagnetic induction principle, measure the volume of conductive fluid flow
01
Classification: EMP
02
Structure form: split
TECHNICAL SPECIFICATIONS
Technical specifications
Check the specifications against your operating conditions and use the selection tables to confirm your order configuration.
View selection tables ↓| Model | FLUME-EM-150 |
|---|---|
| Nominal pipe size | DN15~DN2000 |
| Liner material | PTFE / FEP (F46) / neoprene (CR) / polyurethane (PU) / PFA |
| Connection | Flanged connection |
| Electrode material | 316L, Hastelloy C, Hastelloy B, titanium, tantalum, platinum-iridium alloy, or tungsten carbide-coated stainless steel |
| Housing material | Powder-coated carbon steel / 304 stainless steel / 316 stainless steel (select B1, B2, or B3) |
| Ambient temperature | Sensor: −40 to +80 °C. Converter: −15 to +50 °C. |
| Process medium temperature | ≤150℃ |
| Operating pressure | DN15–DN400: 1.6MPa DN450–DN600 1.0MPa ≥DN700 0.6MPa (specify when ordering) |
| Accuracy class | Class 0.5 at 0.5–5 m/s |
| Communication | RS485 (Modbus protocol), HART |
| Load resistance | ≤750 Ω with 4–20 mA output |
| Medium conductivity | ≥5μS/cm |
| Flow velocity range | 0.5–10m/s (recommended 0.5–5m/s) |
| Display readings | Instantaneous flow, velocity, percentage, empty-pipe ratio, forward and reverse totals, and alarms |
| Ingress protection | IP65 / IP68 |
| Explosion protection marking | Ex d IIB T6 Gb |
| Output signal | Fully isolated 4–20 mA, pulse, and high/low alarm outputs |
| Power consumption | ≤15W |
| Power supply | 220V AC 50Hz、24V DC |
Product selection
FLUME-EM-150| Code | Nominal size (mm) | Measurement range (m³/h) |
|---|---|---|
| 15 | DN15 | 0.32~6.36 |
| 20 | DN20 | 0.57~11.30 |
| 25 | DN25 | 0.88~17.66 |
| 32 | DN32 | 1.45~28.94 |
| 40 | DN40 | 2.26~45.22 |
| 50 | DN50 | 3.35~70.65 |
| 65 | DN65 | 5.97~119.40 |
| 80 | DN80 | 9.04~180.86 |
| 100 | DN100 | 14.13~282.60 |
| 125 | DN125 | 22.08~441.56 |
| 150 | DN150 | 31.79~635.85 |
| 200 | DN200 | 56.52~1130.40 |
| 250 | DN250 | 88.31~1766.25 |
| 300 | DN300 | 127.17~2543.40 |
| 350 | DN350 | 173.09~3461.85 |
| 400 | DN400 | 226.08~4521.60 |
| 450 | DN450 | 286.28~5725.55 |
| 500 | DN500 | 353.43~7068.58 |
| 600 | DN600 | 508.94~10178.76 |
| 700 | DN700 | 692.72~13854.42 |
| 800 | DN800 | 904.78~18095.57 |
| 900 | DN900 | 1145.11~22902.21 |
| 1000 | DN1000 | 1413.72~28274.33 |
| 1200 | DN1200 | 2035.75~40715.04 |
| 1400 | DN1400 | 2770.88~55417.69 |
| 1600 | DN1600 | 3619.11~72382.29 |
| 1800 | DN1800 | 4580.44~91608.84 |
| 2000 | DN2000 | 5654.87~113097.34 |
| Code | Pressure rating |
|---|---|
| P2 | 1.0 MPa |
| P3 | 1.6 MPa |
| P4 | 2.5 MPa |
| P5 | 4.0 MPa |
| Code | Sensor material |
|---|---|
| B2 | 304 Stainless steel |
| B3 | 316 Stainless steel |
| Code | Liner material |
|---|---|
| C1 | PTFE (F4, ≤120℃) |
| C2 | FEP (F46, ≤120℃) |
| C3 | Neoprene (≤65℃) |
| C4 | Polyurethane rubber (≤40℃) |
| C5 | PFA (≤150℃, Vacuum resistance) |
| Code | Electrode material |
|---|---|
| K1 | 316L |
| K2 | Hastelloy B |
| K3 | Hastelloy C |
| K4 | Titanium |
| K5 | Tantalum |
| K6 | Platinum-iridium alloy |
| K7 | Tungsten carbide-coated stainless steel |
| Code | Accuracy class |
|---|---|
| E2 | Level 0.5 |
| Code | Construction |
|---|---|
| S2 | Fragmentation (≤150℃) |
| Code | Power supply |
|---|---|
| D1 | 220V AC 50Hz |
| D2 | 24V DC |
| Code | Signal output |
|---|---|
| F1 | (4~20) mA, frequency, pulse, RS485 (Modbus) |
| F2 | (4~20) mA, frequency, pulse, HART |
| Code | Explosion protection marking |
|---|---|
| U1 | It's blastproof. |
Confirm specifications and ordering options
Contact us with the measurement target, operating conditions, and installation requirements to confirm your configuration.
Contact us