Food and beverages Full-plant programme

Control of evaporation enrichment of dairy products

Density determination endpoints, energy efficiency and quality.

Monitoring of concentrations of concentrate milk online using mass flow meters to determine accurately the evaporation endpoints and avoid enrichment and energy waste.

Control of evaporation enrichment of dairy products

Application Scene

Actual scene

Typical performance in the food and beverage industry

In dairy production, fresh milk is concentrated in membrane devarnishers to the fixed solid content (e.g., milk treated before powder). Concentrations have traditionally been measured by sampling refractive machines, with delays in sampling several times per pot: excessive enrichment wastes steam and time, and insufficient concentrations affect subsequent drying processes. The matching of evaporation feed with the steam supply also directly affects energy consumption.

Our Approach

Recommended configuration

3 related products

The evaporation unit is equipped with a DMF-50 c.c. mass flow meter, which measures on-line the flow and density of strong milk mass: density is stablely correlated with solid content, and real-time concentration signals are used directly to determine evaporation endpoints to reach the default concentration automatically to switch out. The feeder segment configuration of sanitary electromagnetic flowmeters and control valves constitutes a flow-control loop to optimize the vapour supply with temperature differential data, and ton of product evaporation energy consumption can be reduced by more than 5%.

Pain Points

It hurts a little.

  • ! The concentration of artificial sampling was delayed, and over- and under-enrichment was mixed
  • ! Insufficient concentrations into dry processes, non-compliant milk powder quality
  • ! The feed doesn't match the steam supply. Energy consumption is high.

Capabilities

Core competencies

  • ✓ Quality flow meter online density measurement, concentrations continuous in real time
  • ✓ Concentration to limit automatic switching, eliminating re-emission of enrichment
  • ✓ Feed flow closed ring control, evaporation engine stable.
  • ✓ Health-type structures resistant to CIP and acid-based cleaning

You want to know about the program?

Contact us, describe your field work, get targeted options and proposals.

Contact us