Data centre frozen water flow monitoring
Rendering water flow temperature differentials, PUE optimization building blocks
Provide backwater flow and temperature differential monitoring for the data centre refrigeration water system to support refrigeration efficiency and PUE optimization.
Application Scene
Actual scene
Typical data centre industry performance
The data centre refrigeration system provides cooling to the room ' s precision air conditioning and cooling channels: the cooling of the temperature differentials and flows reflects the actual cold load, which is the basis for the cooling unit plus and downtime and the pump frequency; The persistent small temperature differentials indicate excess or poor heat exchange and waste of energy. The electricity consumption of the refrigeration system, which accounts for the total electricity consumption of the data centre above 30%, is the main battlefield for PUE optimization.
Our Approach
Recommended configuration
4 related products
Refrigerated water for the configuration of the water main tube LDG-5000S electromagnetic flowmeter to monitor circulation, and water for the deployment of PT-2088A pressure transmitters and SBW-300A temperature transmitters: real time calculation of cold loads (Q=cm ⁇ T) combined with flow and temperature differentials, data access ring monitoring/group control system, guidance on cooler unit control and water pump frequency reconciliation. The pressure differential monitoring of the water collector determines the end valve state and the abnormal conditions automatically alert the population.
Pain Points
It hurts a little.
- ! Cold loads are not transparent, air fleets and pumps are experienced
- ! The small water temperature differentials are a reflection of excess and wasteful energy consumption
- ! End-end imbalance is difficult to locate, and the cabinet is partially hottightly processed.
Capabilities
Core competencies
- ✓ Flow + temperature differential real-time cold load calculation
- ✓ Objective data on the number of aircrews and the frequency of the pump
- ✓ Sewerage pressure differential monitoring, end-of-pipe imbalance position
- ✓ Supporting PUE fine-tuning target
Related Products
Programme support products
FLUME-EM-100 Electromagnetic Flowmeter
Model FLUME-EM-100
EMP, One-Package. Based on the Faraday EMP, measure the volume of conductive liquid flow.
TEMPSEN-TT-100 Integrated Temperature Transmitter
Type TEMPSEN-TT-100
Integrated temperature transmitters, sensors and transmitters
PRETRAN-DM-100 Diffused Silicon Pressure Transmitter (Compact)
Type PRETRAN-DM-100
Smart-spread silicon pressure transmitter, fine configuration. Spread silicon sensors, high value.
PRETRAN-DM-150 Diffused Silicon Pressure Transmitter (Waterproof)
PRETRAN-DM-150
Smart-spread silicon pressure transmitter, waterproof configuration. Spread silicon sensors, high value.
You want to know about the program?
Contact us, describe your field work, get targeted options and proposals.
Contact us